40055

Manufacturer: Nautilus Hyosung
Model: 1800CE, 1800SE, 2700CE, 2700T, 4000W, 5000CE, 5000SE, 5000XP, 5050CE, 5050XP, 5300CE, 5300XP, Halo
Description: Timeout due to note's length error passed through the CS13 during dispense operation
Solution: The dispenser's CS13 sensor was blocked for too long during a dispense operation.

Corrective steps:

1. Remove any jammed notes and attempt to re-initialize the dispenser.

2. Inspect the CS13 sensor for obstructions. Clean the sensor, if necessary.

3. Check the CS13 sensor cable. Reseat the sensor cable plug on the dispenser control board.

4. Replace the dispenser or send it in for repair.

Repair Item: N/A
Replacement Item: N/A

Contact form